CN3586 Electric Motor for Gas Compression
Get power built for your most demanding gas compression applications. Every Cat® electric motor is tested at each stage of production to make sure it performs reliably under load and according to your process requirements. High operating efficiency and low operating costs come with low noise levels and no emissions. Cat electric motors for gas compression are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.
| Type of EX-Protection | Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC) |
| Mounting Designation | F1 or F2 |
| Voltage/Frequency | 4000V & 4160V ± 10%/60 Hz |
| Type of EX-Protection | Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC) |
| Mounting Designation | F1 or F2 |
| Voltage/Frequency | 4000V & 4160V ± 10%/60 Hz |
| Type of EX-Protection | Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC) |
| Mounting Designation | F1 or F2 |
| Voltage/Frequency | 4000V & 4160V ± 10%/60 Hz |
| Full Load Speed | 894 rpm |
| Electric Motor Type | Squirrel Cage Induction Motor |
| Number of Poles | 8 |
| Maximum Ambient Temperature | 104 °F |
| Full Load Current | 458 Amps |
| Shaft | 8.5 in |
| Rated Torque | 20555 lb/ft |
| Maximum Altitude - Before Derate | 3300 ft |
| Locked Rotor Amps | 540% Code E |
| Connection of Stator Winding | Star |
| Standards | NEMA MG1 |
| Duty | Continuous |
| Enclosure Type/Method of Cooling | WP-II |
| Locked Rotor Torque | 60% |
| Service Factor | 1.15 SF (1.0 VFD) |
| No Load Current | 137 Amps |
| Insulation | Class F |
| Temperature Rise | Class B at rated load |
| Type of EX-Protection | Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC) |
| Mounting Designation | F1 or F2 |
| Voltage/Frequency | 4000V & 4160V ± 10%/60 Hz |
| Full Load Speed | 894 rpm |
| Electric Motor Type | Squirrel Cage Induction Motor |
| Number of Poles | 8 |
| Maximum Ambient Temperature | 40 °C |
| Full Load Current | 458 Amps |
| Shaft | 216 mm |
| Rated Torque | 27869 N·m |
| Maximum Altitude - Before Derate | 1000 m |
| Locked Rotor Amps | 540% Code E |
| Connection of Stator Winding | Star |
| Standards | NEMA MG1 |
| Duty | Continuous |
| Enclosure Type/Method of Cooling | WP-II |
| Locked Rotor Torque | 60% |
| Service Factor | 1.15 SF (1.0 VFD) |
| No Load Current | 137 Amps |
| Insulation | Class F |
| Temperature Rise | Class B at rated load |
Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry's standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it
| 100 | 200 | # | # |
|---|---|---|---|
| 1 | # | 1 | # |